Trigger Device

Product specification

Initiator
Resistance2±0.3Ω(-40°C - +60°C)
Insulation Resistance>1mΩ(500VDC)
No-Fire Current
Reliability
0.4 A(10sec,+ +85°C)
99.9999%(95%CL)
All-Fire Current
Reliability
1.2 A(2ms,-40°C)
99.9999%(95%CL)
Test-Fire Current1.75A/2ms
Product Traceability
Tracing the Source, Upholding Quality — All for Giving You the Best

Each gas generator is labeled with a one-dimensional barcode to enable easy traceability of its origin, ensuring both quality and management efficiency.